June 20, 2024

This article has been reviewed according to Science X's editorial process and policies. Editors have highlighted the following attributes while ensuring the content's credibility:

fact-checked
trusted source
proofread

Turning infrared light visible: New device uses 2D material to up-convert infrared light

From left to right: Schematic of the nonlinear optical mirror used for up-conversion imaging. Energy diagram showing the sum frequency generation process used for up-conversion. Representative up-converted images of IISc logo and spokes where the object pattern at 1,550 nm is upconverted to 622 nm wavelength. Credit: Jyothsna KM
× close
From left to right: Schematic of the nonlinear optical mirror used for up-conversion imaging. Energy diagram showing the sum frequency generation process used for up-conversion. Representative up-converted images of IISc logo and spokes where the object pattern at 1,550 nm is upconverted to 622 nm wavelength. Credit: Jyothsna KM

The human eye can only see light at certain frequencies (called the visible spectrum), the lowest of which constitutes red light. Infrared light, which we can't see, has an even lower frequency than red light. Researchers at the Indian Institute of Science (IISc) have now fabricated a device to increase or "up-convert" the frequency of short infrared light to the visible range.

Up-conversion of light has diverse applications, especially in defense and . In a first, the IISc team used a 2D material to design what they call a non-linear optical mirror stack to achieve this up-conversion, combined with widefield imaging capability. The stack consists of multilayered gallium selenide fixed to the top of a gold reflective surface, with a silicon dioxide layer sandwiched in between.

Traditional infrared imaging uses exotic low-energy bandgap semiconductors or micro-bolometer arrays, which usually pick up heat or absorption signatures from the object being studied.

Infrared imaging and sensing is useful in diverse areas, from astronomy to chemistry. For example, when is passed through a gas, sensing how the light changes can help scientists tease out specific properties of the gas. Such sensing is not always possible using visible light.

However, existing infrared sensors are bulky and not very efficient. They are also export-restricted because of their utility in defense. There is, therefore, a critical need to develop indigenous and efficient devices.

The method used by the IISc team involves feeding an input infrared signal along with a pump beam onto the mirror stack. The nonlinear optical properties of the material constituting the stack result in a mixing of the frequencies, leading to an output beam of increased (up-converted) , but with the rest of the properties intact. Using this method, they were able to up-convert infrared light of wavelength around 1550 nm to 622 nm visible light. The output light wave can be detected using traditional silicon-based cameras.

Lead author Jyothsna KM aligning optical beams for up-conversion experiments. Credit: Harinee Natarajan
× close
Lead author Jyothsna KM aligning optical beams for up-conversion experiments. Credit: Harinee Natarajan

"This process is coherent—the properties of the input beam are preserved at the output. This means that if one imprints a particular pattern in the input infrared frequency, it automatically gets transferred to the new output frequency," explains Varun Raghunathan, Associate Professor in the Department of Electrical Communication Engineering (ECE) and corresponding author of the study published in Laser & Photonics Reviews.

The advantage of using gallium selenide, he adds, is its high optical nonlinearity, which means that a single photon of infrared light and a single photon of the pump beam could combine to give a single photon of light with up-converted frequency.

The team was able to achieve the up-conversion even with a thin layer of gallium selenide measuring just 45 nm. The makes it more cost-effective than traditional devices that use centimeter-sized crystals. Its performance was also found to be comparable to current state-of-the-art up-conversion imaging systems.

Jyothsna K Manattayil, Ph.D. student at ECE and first author, explains that they used a particle swarm optimization algorithm to speed up the calculation of the right thickness of layers needed. Depending on the thickness, the wavelengths that can pass through gallium selenide and get up-converted will vary. This means that the material thickness needs to be tweaked depending on the application.

"In our experiments, we have used infrared light of 1,550 nm and a pump beam of 1,040 nm. But that doesn't mean that it won't work for other wavelengths," she says. "We saw that the performance didn't drop for a wide range of infrared wavelengths, from 1,400 nm to 1,700 nm."

Going forward, the researchers plan to extend their work to up-convert light of longer wavelengths. They are also trying to improve the efficiency of the device by exploring other stack geometries.

"There is a lot of interest worldwide in doing infrared imaging without using infrared sensors. Our work could be a gamechanger for those applications," says Raghunathan.

More information: Jyothsna Konkada Manattayil et al, 2D Material Based Nonlinear Optical Mirror for Widefield Up‐Conversion Imaging from Near Infrared to Visible Wavelengths, Laser & Photonics Reviews (2024). DOI: 10.1002/lpor.202400374